{"id":6738,"date":"2026-11-18T13:04:22","date_gmt":"2026-11-18T13:04:22","guid":{"rendered":"https:\/\/www.lab-sun.de\/?page_id=6738"},"modified":"2026-11-21T03:38:38","modified_gmt":"2026-11-21T03:38:38","slug":"colour-measurement-in-pharmaceutical-quality-control","status":"publish","type":"page","link":"https:\/\/www.lab-sun.de\/en\/applications\/colour-measurement-in-pharmaceutical-quality-control\/","title":{"rendered":"Colour Measurement in Pharmaceutical Quality Control"},"content":{"rendered":"<article class=\"labsun-lovibond-application\">\n<h2>Measurement task<\/h2>\n<p>Compare the colour of pharmaceutical samples with a defined reference or compare colour differences between batches. Use transmission for transparent solutions and reflectance for suitable solid surfaces. The test procedure determines the scale, sample presentation and acceptance criteria.<\/p>\n<h2>Sample conditions<\/h2>\n<p>For transparent liquids, confirm the sample volume, the cell material and the required optical path length. For tablets and capsules, check whether the available surface area and curvature suit the measurement aperture. Powders, gels and pastes need a suitable holder and a reproducible preparation procedure.<\/p>\n<h2>Method and colour scale<\/h2>\n<p>Confirm the required European Pharmacopoeia (Ph. Eur.), United States Pharmacopeia (USP) or internal test procedure before selecting the instrument. A visual comparator compares the sample with the reference set specified for the method. An instrumental configuration measures transmission or reflectance with the geometry and reporting format required for the sample.<\/p>\n<h2>Instrument and configuration<\/h2>\n<ul>\n<li><strong>Instrumental transmission.<\/strong> The model-specific table for <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-pfxi-195-5-automatic-colour-measurement-instrument\/\" hreflang=\"de\">PFXi-195\/5 (1371955, German)<\/a> specifies a 40 mm optical path for EP and USP scales and 50 mm for Pt-Co.<\/li>\n<li><strong>Visual comparison.<\/strong> <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-comparator-2000-af332-european-pharmacopoeia-colour-kit\/\" hreflang=\"de\">AF332 (433320, German)<\/a> is the EP comparator configuration. <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-comparator-2000-af335-united-states-pharmacopeia-colour-kit\/\" hreflang=\"de\">AF335 (433350, German)<\/a> is the USP configuration. Confirm the reference set and sample vessels for the chosen procedure.<\/li>\n<li><strong>Reflectance.<\/strong> Compare the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-tr-520-handheld-reflectance-spectrophotometer\/\" hreflang=\"de\">TR 520 (403035, German)<\/a> and <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-lc-100-handheld-reflectance-spectrocolorimeter\/\" hreflang=\"de\">LC 100 (401100, German)<\/a> for solid surfaces. For powders and pastes, review sample presentation and holder compatibility with the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-lc-100-and-sv-100-reflectance-measurement-kit\/\" hreflang=\"de\">LC 100 \/ SV 100 kit (401120, German)<\/a> or a complete system such as the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-tra-500-handheld-and-benchtop-reflectance-system\/\" hreflang=\"de\">TRA 500 (403220, German)<\/a>.<\/li>\n<\/ul>\n<figure class=\"labsun-lovibond-application-photo\" style=\"margin:16px 0 24px;max-width:480px;background:#fff;border:1px solid #e1e8ed;border-radius:8px;overflow:hidden\">\n    <img loading=\"lazy\" src=\"https:\/\/www.lab-sun.de\/wp-content\/uploads\/2026\/11\/lovibond-tr-520-tra-520-zh-600x600.jpg\" srcset=\"https:\/\/www.lab-sun.de\/wp-content\/uploads\/2026\/11\/lovibond-tr-520-tra-520-zh-300x300.jpg 300w, https:\/\/www.lab-sun.de\/wp-content\/uploads\/2026\/11\/lovibond-tr-520-tra-520-zh-600x600.jpg 600w\" sizes=\"auto, (max-width: 600px) 85vw, 480px\" width=\"600\" height=\"600\" loading=\"lazy\" decoding=\"async\" alt=\"Lovibond TR-series reflectance spectrophotometer\" style=\"display:block;width:100%;height:clamp(180px,34vw,260px);object-fit:contain\"><figcaption style=\"padding:7px 11px 9px;font-size:14px;line-height:1.45;color:#38556a\">Lovibond TR series for reflectance measurements.<\/figcaption><\/figure>\n<h2>Cells and verification materials<\/h2>\n<p>Match the PFXi-195\/5 method to the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-w600-og-optical-glass-cuvette-40-mm\/\" hreflang=\"de\">W600\/OG\/40 cell (606020, German)<\/a> for the 40 mm path or the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-w600-og-50-optical-glass-cuvette-50-mm\/\" hreflang=\"de\">W600\/OG\/50 cell (606200, German)<\/a> for the 50 mm path. Use the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-ep-y-glass-conformance-filter-nominal-4\/\" hreflang=\"de\">EP Y glass filter (131045, German)<\/a> for its specified EP yellow-scale conformance check. Select any required liquid reference separately. The <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-10-mm-disposable-plastic-cuvettes-100\/\" hreflang=\"de\">10 mm disposable cell (132750, German)<\/a> is listed for LC 100 \/ SV 100.<\/p>\n<h2>Application limits<\/h2>\n<p>Qualify the instrument, accessories and software against the specific pharmacopoeial or internal procedure. Assess reflectance results using the specified surface measurement method. Confirm the reference, software and documentation requirements for the quoted configuration.<\/p>\n<h2>Manufacturer documentation<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%201371955%20-%20PFXi-1955%20de.pdf\">PFXi-195\/5 model-specific data sheet (German, PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20433320%20-%20AF332%20EP-Farbskala%20%28Eur.%20Arzneibuch%20Methode%202.2.2%29%20de.pdf\">AF332 EP comparator data sheet (German, PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20433350%20-%20AF335%20USP-Farbskala%20de.pdf\">AF335 USP comparator data sheet (German, PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20403035%20-%20TR%20520%20Spektralphotometer%20de.pdf\">TR 520 reflectance spectrophotometer data sheet (German, PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20401100%20-%20LC%20100%20Spektralkolorimeter%20de.pdf\">LC 100 spectrocolorimeter data sheet (German, PDF)<\/a><\/li>\n<\/ul>\n<h2>Request a quotation<\/h2>\n<p>Tell Labsun GmbH the sample type and volume or usable surface area, the test procedure, target colour scale and any documentation or software requirements. Labsun can help specify the instrument, sample holder and verification materials for a quotation.<\/p>\n<p><a class=\"button\" href=\"https:\/\/www.lab-sun.de\/en\/contact\/?labsun_product_enquiry=Application%20enquiry%3A%20Colour%20measurement%20in%20pharmaceutical%20quality%20control#fluentform_1\">Enquire about pharmaceutical colour measurement<\/a><\/p>\n<\/article>\n","protected":false},"excerpt":{"rendered":"<p>Select transmission, reflectance or visual colour comparison for a defined pharmaceutical sample and test procedure.<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":5527,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6738","page","type-page","status-publish","hentry"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"_links":{"self":[{"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages\/6738","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/comments?post=6738"}],"version-history":[{"count":1,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages\/6738\/revisions"}],"predecessor-version":[{"id":6740,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages\/6738\/revisions\/6740"}],"up":[{"embeddable":true,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages\/5527"}],"wp:attachment":[{"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/media?parent=6738"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}