{"id":6744,"date":"2026-11-18T13:11:53","date_gmt":"2026-11-18T13:11:53","guid":{"rendered":"https:\/\/www.lab-sun.de\/?page_id=6744"},"modified":"2026-11-21T03:53:27","modified_gmt":"2026-11-21T03:53:27","slug":"colour-measurement-of-cosmetics-powders-and-solid-surfaces","status":"publish","type":"page","link":"https:\/\/www.lab-sun.de\/en\/applications\/colour-measurement-of-cosmetics-powders-and-solid-surfaces\/","title":{"rendered":"Colour Measurement of Cosmetics, Powders and Solid Surfaces"},"content":{"rendered":"<article class=\"labsun-lovibond-application\">\n<h2>Measurement task<\/h2>\n<p>Compare the colour of suitable cosmetics, powders, pastes and solid surfaces against a defined reference. Use the same measurement settings and sample presentation when comparing batches or assessing a colour difference.<\/p>\n<figure class=\"labsun-lovibond-application-photo\" style=\"margin:16px 0 24px;max-width:480px;background:#fff;border:1px solid #e1e8ed;border-radius:8px;overflow:hidden\">\n    <img loading=\"lazy\" src=\"https:\/\/www.lab-sun.de\/wp-content\/uploads\/2026\/11\/lovibond-lc-100-sv-100-zh-600x600.jpg\" srcset=\"https:\/\/www.lab-sun.de\/wp-content\/uploads\/2026\/11\/lovibond-lc-100-sv-100-zh-300x300.jpg 300w, https:\/\/www.lab-sun.de\/wp-content\/uploads\/2026\/11\/lovibond-lc-100-sv-100-zh-600x600.jpg 600w\" sizes=\"auto, (max-width: 600px) 85vw, 480px\" width=\"600\" height=\"600\" loading=\"lazy\" decoding=\"async\" alt=\"Lovibond LC 100 \/ SV 100 reflectance measurement kit\" style=\"display:block;width:100%;height:clamp(180px,34vw,260px);object-fit:contain\"><figcaption style=\"padding:7px 11px 9px;font-size:14px;line-height:1.45;color:#38556a\">Lovibond LC 100 \/ SV 100 reflectance measurement kit.<\/figcaption><\/figure>\n<h2>Sample conditions<\/h2>\n<p>Confirm the usable surface area, texture, gloss and homogeneity. For a powder or paste, define the fill, packing density, layer and background, and position each sample consistently. The holder and cleaning procedure must suit the sample material.<\/p>\n<h2>Method and colour scale<\/h2>\n<p>Use reflectance under defined measurement geometry. Set the aperture and sample presentation, including the background and the illuminant and observer conditions required by the method. Evaluate the colour difference against the specified reference under the same configuration.<\/p>\n<h2>Instrument and configuration<\/h2>\n<ul>\n<li>For a suitable solid surface, consider the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-lc-100-handheld-reflectance-spectrocolorimeter\/\" hreflang=\"de\">LC 100 (401100, German)<\/a>. For a sample that needs a viewing stand and holder, check the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-lc-100-and-sv-100-reflectance-measurement-kit\/\" hreflang=\"de\">LC 100 \/ SV 100 kit (401120, German)<\/a>.<\/li>\n<li>Compare the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-tr-520-handheld-reflectance-spectrophotometer\/\" hreflang=\"de\">TR 520 (403035, German)<\/a> for a defined reflectance geometry. Confirm the aperture and UV settings for the exact model and method.<\/li>\n<li>For suitable non-solid samples, check the presentation options of the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-tra-500-handheld-and-benchtop-reflectance-system\/\" hreflang=\"de\">TRA 500 (403220, German)<\/a> and <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-tra-520-handheld-and-benchtop-reflectance-system\/\" hreflang=\"de\">TRA 520 (403225, German)<\/a>. Both are complete spectrophotometer configurations with a TRA sample holder.<\/li>\n<\/ul>\n<h2>Cells and verification materials<\/h2>\n<p>Use the <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-10-mm-disposable-plastic-cuvettes-100\/\" hreflang=\"de\">10 mm disposable plastic cell (132750, German)<\/a> for the LC 100 \/ SV 100 setup if the sample and method are compatible. For the TRA holder, the manufacturer lists optical-glass cells including <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-w586-og-optical-glass-cuvette-10-mm\/\" hreflang=\"de\">W586\/OG\/10 (605890, German)<\/a>, <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-w586-og-optical-glass-cuvette-20-mm\/\" hreflang=\"de\">W586\/OG\/20 (605900, German)<\/a> and <a href=\"https:\/\/www.lab-sun.de\/en\/products\/lovibond-w586-og-optical-glass-cuvette-30-mm\/\" hreflang=\"de\">W586\/OG\/30 (605910, German)<\/a>. Check which cells the configuration includes before ordering spares. Use calibration tiles and verification references as specified in the instrument manual.<\/p>\n<h2>Application limits<\/h2>\n<p>Gloss, texture, packing and sample geometry can all influence the result. Interpret reflectance results under the specified surface measurement method. PFXi transmission colour scales require a separate method for suitable liquids. Verify aperture and UV options for the selected TR or TRA model.<\/p>\n<h2>Manufacturer documentation<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20401100%20-%20LC%20100%20Spektralkolorimeter%20de.pdf\">LC 100 data sheet (German, PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20401120%20-%20LC%20100%20SV%20100%20Kit%20de.pdf\">LC 100 \/ SV 100 kit data sheet (German, PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20403035%20-%20TR%20520%20Spektralphotometer%20de.pdf\">TR 520 data sheet (German, PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20403220%20-%20TRA%20500%20Spektralphotometer%20de.pdf\">TRA 500 data sheet (German, PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.lovibond.com\/ix_pim_assets\/datasheet\/colour\/de\/Datenblatt%20403225%20-%20TRA%20520%20Spektralphotometer%20de.pdf\">TRA 520 data sheet (German, PDF)<\/a><\/li>\n<\/ul>\n<h2>Request a quotation<\/h2>\n<p>Tell Labsun GmbH the sample type and condition, its size or available measurement area, the required colour comparison and any reference materials. Labsun can help specify the instrument, sample holder and accessories for a quotation.<\/p>\n<p><a class=\"button\" href=\"https:\/\/www.lab-sun.de\/en\/contact\/?labsun_product_enquiry=Application%20enquiry%3A%20Colour%20measurement%20of%20powders%20and%20solid%20surfaces#fluentform_1\">Enquire about powder and surface colour measurement<\/a><\/p>\n<\/article>\n","protected":false},"excerpt":{"rendered":"<p>Compare reflectance configurations for cosmetics, powders, pastes and solid surfaces, with guidance on sample holders and verification materials.<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":5527,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6744","page","type-page","status-publish","hentry"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"_links":{"self":[{"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages\/6744","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/comments?post=6744"}],"version-history":[{"count":1,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages\/6744\/revisions"}],"predecessor-version":[{"id":6748,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages\/6744\/revisions\/6748"}],"up":[{"embeddable":true,"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/pages\/5527"}],"wp:attachment":[{"href":"https:\/\/www.lab-sun.de\/en\/wp-json\/wp\/v2\/media?parent=6744"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}