Herolab UniCen MR Refrigerated Universal Benchtop Centrifuge

Article No.: LS-21 14 065

The Herolab UniCen MR is a refrigerated universal benchtop centrifuge. Depending on the rotor installed, it achieves speeds of up to 24,000 rpm, an RCF of up to 45,078 × g and a capacity of up to 4 × 200 mL. This refrigerated configuration is intended for workflows in which temperature control is an integral part of the centrifugation process.

Herolab UniCen MR Refrigerated Universal Benchtop Centrifuge
SKU: LS-21 14 065 Categories: , Brand:

The UniCen MR is configured with the appropriate rotor, buckets, adapters and sample vessels for the intended workflow. Selection is based not only on speed and RCF, but also on vessel format, required throughput and the permitted rotor loading configuration.

Speed, RCF and capacity values depend on the rotor configuration. To prepare a quotation, please specify the sample volume, vessel type, target RCF, temperature requirements and existing laboratory workflow.

Technical Specifications

Parameter Specification
Design refrigerated universal benchtop centrifuge
Maximum speed up to 24,000 rpm
Maximum RCF up to 45,078 × g
Maximum capacity up to 4 × 200 mL
Refrigeration yes
Rotors and adapters selectable according to the sample vessel and application

The available order numbers and associated options are listed below.

Item Article No. Description
1 LS-21 14 065 Herolab UniCen MR — base unit
2 on request Rotors, buckets and adapters for the UniCen MR
3 on request Compatible centrifuge tubes and bottles

Which samples is the UniCen MR suitable for?
Suitability depends on the selected rotor, adapter and permitted vessel configuration.

Why is the rotor part of the ordering configuration?
Speed, RCF, capacity and vessel format are determined by the specific rotor configuration.

What does RCF mean?
RCF is the relative centrifugal force expressed in × g. In addition to speed, it depends on the rotor radius.

What information is required for a quotation?
Please provide the sample volume, vessel type, number of samples, target RCF and any temperature-control requirements.

Is refrigeration required?
A refrigerated model should be selected when the workflow or sample requires temperature control during centrifugation.

Can existing tubes continue to be used?
Compatibility is assessed using the outer dimensions, length, material, permitted RCF and available adapter.