Cell and tissue collection

Collect individual cells and selected tissue regions using a suitable inverted microscope.

Manufacturer: NeuroInDx (NDX)

Request a quote →

Example configurations. Pictured microscope components are included only when listed in the quotation.

Models & technical specifications

Swipe the table left or right to compare all three models.

Parameter UnipicK UnipicK+ A-picK
Control Analogue, manual Digital touchscreen PC with PIKCELLS
Microscope integration Add-on for an inverted microscope Integrated or add-on mounting Integrated with Olympus IX73/IX83
Automation Manual operation Optional, on request Software-controlled
Maximum vacuum 10 PSI (≈69 kPa) 10 PSI (≈69 kPa) 10 PSI (≈69 kPa)
Maximum positive pressure Not specified 5 PSI (≈34.5 kPa) 5 PSI (≈34.5 kPa)
Pulse duration 0.1–1.0 s 0.1–1.0 s 0.1–1.0 s
Travel step Vertical: 1.5 µm 1.5 µm 1.5 µm
Sampling resolution Single cells in culture; 20 µm in tissue sections Single cells in culture; 20 µm in tissue sections Single cells in culture; 20 µm in tissue sections
Cell viability Up to 99% Up to 99% Up to 95%
Reference speed Tissue: up to 12 cells/min; cultures: up to 25 cells/min Tissue: up to 12 cells/min; cultures: up to 25 cells/min Up to 25 collection/deposition cycles/min
Samples per run Protocol-dependent Configuration-dependent Up to 48
Model enquiry UnipicK → UnipicK+ → A-picK →

Manufacturer specifications under the stated experimental conditions; kPa values are rounded conversions from PSI. Viability refers to suitable live cells; reference speed depends on the protocol. Travel step and sampling resolution are different parameters. A-picK supports suitable 96-/384-well plates with up to 48 samples per run.

Collection volume by DCU inner diameter: 20 µm: 10 nl–2.5 µl; 30 µm: 35 nl–3.0 µl; 40 µm: 70 nl–5.0 µl. Medium, viscosity and pulse settings affect the result.

Applications

A DCU capillary collects the selected sample with a vacuum pulse and transfers it to the receiving vessel. UnipicK+ and A-picK support pressure-controlled deposition.

Application Use and models
Cell collection Single cells, rare cells and cell groups for RNA, DNA or protein analysis. All three models.
Tissue microdissection Selected regions of native or fresh-frozen sections for molecular analysis. All three models.
3D cultures & microfluidics 3D cultures and organoids: all three models. Microfluidic chips: described for UnipicK+ and A-picK.
Fixed tissue / FFPE Described for UnipicK+ and A-picK with a specific preparation or liquefaction protocol.
Cell adhesion Adhesion and detachment studies with UnipicK+ or A-picK and a defined measurement protocol.

Match preparation, DCU and collection protocol to the sample, vessel and downstream analysis. Cell suspensions require an adapted protocol.

Further research fields

Stem-cell selection, cancer research, neuroscience, genomics and proteomics. CTC collection is possible from suitable prepared samples; cell identification is performed separately.

Downloads

NeuroInDx brochures, manuals and series catalogue in English – download directly from Labsun.

Series catalogue: UnipicK, UnipicK+, A-picK · EN · PDF

Application videos

View videos by model

Original NDX installation and application videos – play on this page via YouTube.

UnipicK

UnipicK: setup
UnipicK: Purkinje cell collection and deposition

UnipicK+

UnipicK+: system introduction
UnipicK+: A549 cell collection and deposition

A-picK: Tissue and organoids

NDX application example for A-picK: microdissection of an iPSC-derived kidney organoid.

Organoid microdissection: iPSC-derived kidney tissue
More cell and tissue videos
UnipicK+: 3T3 cells
UnipicK+: CHO cells
Retina microdissection: NDX application example
Historical KuiqpicK demonstrations

KuiqpicK is discontinued. These earlier recordings illustrate the method, not the current supply configuration.

KuiqpicK: GFP SH-SY5Y cell (historical)
KuiqpicK: IEC-6 cells (historical)
KuiqpicK: CA3 tissue region (historical)
KuiqpicK: Purkinje cells (historical)

Publications

View four selected studies

The studies document the stated samples, system versions and experimental protocols.

Part numbers and included components

Base components from the series catalogue. The Labsun quotation defines the complete scope of supply.

Model NDX part number Base components
UnipicK U010 Collection head and controller.
UnipicK+ UP010 Collection head, controller and universal sample-holder set for culture dishes and slides, including a 48-tube holder.
A-picK AP010 Collection head, controller, USB 3.0 CMOS camera, PIKCELLS software and universal sample-holder set for culture dishes and slides, including a 48-tube holder.

Microscope and required equipment

Not every inverted microscope is suitable. The microscope, optics, stage, mounting and any automation require technical confirmation before ordering.

UnipicK
Add-on mounting with a straddle suited to the microscope.
UnipicK+
Integrated examples: Olympus CKX41, IX73 and IX83; add-on mounting is an alternative. Optional automation uses a Märzhäuser SCAN IM 120×80 stage, software and a suitable holder; it is not included in the UP010 base package. PC requirements depend on the configuration.
A-picK
Integration with Olympus IX73/IX83; other microscopes require technical approval. Documented operating setup: SCAN IM 120×80, PIKCELLS, a PC with monitor and mouse, and a 5 MP USB 3.0 CMOS camera. The PC, microscope and motorised stage are not listed as AP010 base components.

All models require suitable DCUs.

UnipicK mounting note

The manual describes a universal stand, alignment tool, cables and power supply. The upper microscope illumination is temporarily removed for installation. DCUs and filter attachments are supplied separately.

Software upgrade from an earlier catalogue

UPA01 identifies a software upgrade for automating UnipicK+ with Märzhäuser stages. It is not a separate instrument model or a complete automated system. Current availability and compatibility are confirmed on request.

Accessories and consumables

Component NDX part number Selection
DCU capillaries DCUXXX; DCU010–DCU100 10–100 µm inner diameter, 6/pack; sterile, ready-to-use borosilicate glass. For adherent cultures: 20–50 µm as a starting point. Custom diameters on request.
Microscope straddle U020 Bridge, legs, head adapter and calibration unit for UnipicK and UnipicK+.
Direct adapter CKX31/CKX41 U030 Model-dependent direct adapter for Olympus.
Direct adapter IX51/IX71/IX81 U035 Model-dependent direct adapter for Olympus.
Direct adapter IX73/IX83 U040 Model-dependent direct adapter for Olympus.
Universal sample holder U050 For slides, dishes, PCR vessels, 8-tube strips and 48-well plates. A sample-holder set is included in the catalogue packages UP010 and AP010; order extra holders only if needed. Confirm holder/software compatibility for automation.
Slide heating system HSC01 Heating stage, controller and holder; the current accessories description specifies 20–120 °C in 0.1 °C increments. Confirm the range for the quoted version.
DCU sterilisation tray DCU-ST Holds 12 DCUs.
Filter attachments Not published Separate consumable per manual; type and quantity in quotation.

DCU inner diameter does not necessarily equal the tissue region collected. For DCUs, specify the part number or inner diameter and number of packs; for mounting accessories, specify the microscope model.

Request a quote →

Frequently asked questions

Can I use my existing microscope?

Tell us the manufacturer, model, optics and stage configuration. We will check the appropriate setup; see Microscope and required equipment.

What preparation is needed for automated workflows?

Target selection, calibration and a sample-specific protocol remain necessary. Model-specific equipment and options: Microscope and required equipment.

Which samples and preparation methods are suitable?

Typical samples include adherent cell cultures and native or fresh-frozen tissue sections; 3D cultures and organoids are also possible applications. Suspensions require adapted protocols; special procedures for fixed specimens, including FFPE, are described for UnipicK+ and A-picK. Fixation is not a general prerequisite; staining may help identify targets.

Can I select fluorescently labelled targets?

Yes, with suitable fluorescence optics, illumination, filters and sample access. The systems collect selected targets; cell identification uses a separate method.

Do cells remain viable and suitable for downstream analysis?

Live cells can be collected for reculture or clonal expansion; RNA, DNA and protein analyses are possible downstream applications. Results depend on the sample, preparation and collection parameters; fixed specimens cannot be recultured.

Which receiving vessels can be used?

Slides, dishes and PCR vessels can be used depending on the holder. A-picK offers single-cell and pooled-cell modes with up to 48 samples per run. Compatibility with 96-/384-well plates does not increase this to 96 or 384 samples.

How do I select DCUs, and can they be reused?

Selection depends on cell size, tissue and protocol; inner diameter does not necessarily equal the collected tissue region. DCUs are described as sterile capillaries with 10–100 µm inner diameters in packs of six; ordering details are under Accessories and consumables. Reuse requires an intact tip and suitable cleaning, sterilisation and contamination control; unlimited reuse is not assured.

How are installation, training and service arranged?

Installation, training and protocol-support requirements, scope and costs are agreed in the quotation. Lead time, warranty and service terms are also specified there.