Labsun Platinum 80 – High-Strength Silicone Tubing for Higher-Pressure Applications

Item No.:

  • LS-PT80T-XXX-XXX

Labsun Platinum 80 is platinum-cured silicone tubing with a Shore A hardness of 80 for higher-pressure and higher-flow transfer applications. It is intended for pharmaceutical, biotechnology, and laboratory applications that require firmer tubing than softer transfer grades. Its transparent surface supports visual process monitoring.

Labsun Platinum 80 – High-Strength Silicone Tubing for Higher-Pressure Applications

Platinum 80 extends the Labsun tubing portfolio with a firmer silicone grade for higher-pressure applications. The product documentation specifies substantial burst-pressure margins, manufacturing in an ISO Class 7 cleanroom, and available validation documentation. A universal allowable working pressure cannot be stated because it depends on dimensions, temperature, process medium, connection method, and safety factor. Pressure limits must therefore be defined using the approved specification and the specific assembly.

Technical Specifications

Parameter Specification
Material Platinum-cured silicone
Hardness Shore A 80
Primary application Higher-pressure and higher-flow fluid transfer
Color Transparent
Temperature range −50 °C to 200 °C according to the manufacturer
Manufacturing Extruded in an ISO Class 7 cleanroom according to the manufacturer
Referenced tests Including USP Class VI, ISO 10993, EP 3.1.9, and BPOG extractables according to the product documentation
Pressure rating Only according to the dimension- and assembly-specific specification

Standard items; custom lengths, packaging, and assemblies available upon request.

Item Item No. Description
1 LS-PT80T-031-156 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 0.79 mm (0.031 in), OD: 3.96 mm (0.156 in), wall thickness: 1.59 mm (0.063 in)
2 LS-PT80T-063-188 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 1.60 mm (0.063 in), OD: 4.78 mm (0.188 in), wall thickness: 1.59 mm (0.063 in)
3 LS-PT80T-125-250 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 3.18 mm (0.125 in), OD: 6.35 mm (0.250 in), wall thickness: 1.59 mm (0.063 in)
4 LS-PT80T-188-313 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 4.78 mm (0.188 in), OD: 7.95 mm (0.313 in), wall thickness: 1.59 mm (0.063 in)
5 LS-PT80T-188-375 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 4.78 mm (0.188 in), OD: 9.53 mm (0.375 in), wall thickness: 2.37 mm (0.094 in)
6 LS-PT80T-250-375 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 6.35 mm (0.250 in), OD: 9.53 mm (0.375 in), wall thickness: 1.59 mm (0.063 in)
7 LS-PT80T-250-438 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 6.35 mm (0.250 in), OD: 11.13 mm (0.438 in), wall thickness: 2.39 mm (0.094 in)
8 LS-PT80T-250-500 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 6.35 mm (0.250 in), OD: 12.70 mm (0.500 in), wall thickness: 3.18 mm (0.125 in)
9 LS-PT80T-313-438 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 7.95 mm (0.313 in), OD: 11.13 mm (0.438 in), wall thickness: 1.59 mm (0.063 in)
10 LS-PT80T-313-500 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 7.95 mm (0.313 in), OD: 12.70 mm (0.500 in), wall thickness: 2.37 mm (0.094 in)
11 LS-PT80T-375-563 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 9.53 mm (0.375 in), OD: 14.30 mm (0.563 in), wall thickness: 2.39 mm (0.094 in)
12 LS-PT80T-375-625 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 9.53 mm (0.375 in), OD: 15.88 mm (0.625 in), wall thickness: 3.18 mm (0.125 in)
13 LS-PT80T-375-750 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 9.53 mm (0.375 in), OD: 19.05 mm (0.750 in), wall thickness: 4.76 mm (0.188 in)
14 LS-PT80T-375-875 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 9.53 mm (0.375 in), OD: 22.23 mm (0.875 in), wall thickness: 6.35 mm (0.250 in)
15 LS-PT80T-500-750 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 12.70 mm (0.500 in), OD: 19.05 mm (0.750 in), wall thickness: 3.18 mm (0.125 in)
16 LS-PT80T-500-875 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 12.70 mm (0.500 in), OD: 22.23 mm (0.875 in), wall thickness: 4.76 mm (0.188 in)
17 LS-PT80T-500-1000 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 12.70 mm (0.500 in), OD: 25.40 mm (1.000 in), wall thickness: 6.35 mm (0.250 in)
18 LS-PT80T-625-875 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 15.88 mm (0.625 in), OD: 22.23 mm (0.875 in), wall thickness: 3.18 mm (0.125 in)
19 LS-PT80T-625-1000 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 15.88 mm (0.625 in), OD: 25.40 mm (1.000 in), wall thickness: 4.76 mm (0.188 in)
20 LS-PT80T-750-1250 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 19.05 mm (0.750 in), OD: 31.75 mm (1.250 in), wall thickness: 6.35 mm (0.250 in)
21 LS-PT80T-1000-1375 Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, ID: 25.40 mm (1.000 in), OD: 34.93 mm (1.375 in), wall thickness: 4.76 mm (0.188 in)
22 Upon request Labsun, fluid transfer at elevated pressure and flow rates, platinum-cured silicone, custom dimensions: ID, OD, and wall thickness according to customer specification

What is Platinum 80 designed for?
It is designed for transfer applications involving elevated pressure or flow rates in pharmaceutical, biotechnology, and laboratory processes.

Why is the Shore A 80 hardness relevant?
The firmer tubing supports dimensional stability under higher mechanical loads.

What is the maximum working pressure of Platinum 80?
A universal working pressure is not specified. It must be established for the tubing size, temperature, process medium, connection, and applicable safety factor.

Is the tubing transparent?
Yes. The transparent tubing wall facilitates visual process monitoring.

Is validation documentation available?
The product documentation references several biological and extractables-related tests. The documentation package required for the project must be confirmed.

Are custom sizes available?
Custom dimensions and assemblies may be requested subject to technical review.

Contact form
Enquiry / Quotation / Order
Phone:+49 (0)721 47080525
Fax:+49 (0)721 47080537
Email:info@lab-sun.de
Technical Customer Service
Phone:+49 (0) 721 47080579
Email:info@lab-sun.de