Ductless Filtering Fume Hood, 1300–1800 mm, 460–690 m³/h Airflow

High-quality ductless filtering fume hoods: As a supplement to the exhaust air fume hood, they are used for chemical pretreatment experiments and reaction tests for instrument operation.

  • Overall width (mm): 1300, 1500, 1800 
  • Airflow (m³/h): 460, 690

Price: On request

Ductless Filtering Fume Hood, 1300–1800 mm, 460–690 m³/h Airflow
Category: Brand:

ductless filtering fume hoods (benchtop, built-in and custom configurations): They can be integrated at any time and offer safe protection for various routine laboratory procedures and equipment operation on the laboratory work surface. Their containment performance significantly exceeds that of conventional exhaust systems. Flexible and can be integrated into the laboratory work surface at any time. Real-time monitoring of filter performance, air velocity, temperature and humidity.

 

Technical Specifications:

  • Overall width (mm): 1300, 1500, 1800 
  • Airflow (m³/h): 460, 690 
  • Filter module columns: 2, 3 (only available in 1800 series)

 

Download documents:

Pos. Item No.  Description
System
1 LS-AEH900 transparent back for teaching purposes
2 LS-AFH900-M-BT air fume hood, L900, benchtop
3 LS-AFH900-M-OF air fume hood, L900, on floor
4 LS-AFH1302-M-BT air fume hood, L1300, benchtop
5 LS-AFH1302-M-OF air fume hood, L1300, on floor
6 LS-AFH1504-M-BT air fume hood, L1500, benchtop
7 LS-AFH1503-M-OF air fume hood, L1500, on floor
8 LS-AFH1804-M-BT air fume hood, L1800, benchtop
9 LS-AFH1804-M-OF air fume hood, L1800, on floor
10 LS-AIH1302-BT air fume hood, equipment protection, L1300, benchtop
11 LS-AIH1502-BT air fume hood, equipment protection, L1500, benchtop
12 LS-AIH1802-BT air fume hood, equipment protection, L1800, benchtop
13 LS-AWIH1502-OF air fume hood, equipment protection, L1500, on floor step in
14 LS-AWIH1803-OF air fume hood, equipment protection, L1800, on floor step in
15 LS-ATH1503 integrated air fume hood system, L1500, including table, exhaust tube required
16 LS-ATH1804 integrated air fume hood system, L1800, including table, exhaust tube required
consumables
17 LS-AF4A-V filter of organic subs, with min effect on inorganic subs. L900
18 LS-AF4B-V filter of organic subs, with min effect on inorganic subs. L1300
19 LS-AF4A-M comprehensive filter of organic & inorganic subs., L900
20 LS-AF4B-M comprehensive filter of organic & inorganic subs., L1300
21 LS-AF4A-F filter of formaldehyde, L900
22 LS-AF4B-F filter of formaldehyde, L1300
23 LS-AF4A-A filter of ammonia,L900
24 LS-AF4B-A filter of ammonia,L1300
25 LS-AHP-A medical grade filter,H14, L900
26 LS-AHP-B medical grade filter,H14, L1300
27 LS-PF900 pre-filter, L900
28 LS-PF1302 pre-filter, L1300
Service
29 LS-AXH-S annual service

 

Question: What are the ductless filter extractors used for?

Answer: They are used for defined chemical pretreatment, reaction experiments and device operation when a flexible filter solution is required.

Question: What advantages does a ductless filter extractor offer?

Answer: It can be used without a classic exhaust duct and therefore allows for flexible installation in the laboratory, provided the application matches the filter technology.

Question: What sizes and Airflows are available?

Answer: Overall widths of 1300, 1500 and 1800 mm as well as Airflow rates of 460 to 690 m3/h are described.

Question: For which applications is the protective cabin suitable?

Answer: It is suitable for appropriate chemical work, sample preparation and device operation where filter performance and application are compatible.

Question: What should be checked before selection?

Answer: Check chemical list, quantities, application temperature, filter type, safety requirements and whether a ductless exhaust is permitted.