Recommended Workflow
For optimal recovery across the full SVOC range, use the 8270 Disk in a combined disk stack with two Empore™ Activated Carbon Disks:
- 8270 Disk on top — retains the target SVOCs
- 2 × Activated Carbon Disks below — capture polar and reactive compounds
After loading the acidified water sample, dry the stack, invert it, and perform reverse elution: first with DCM/methanol for the acidic/neutral fraction, followed by DCM/methanolic ammonia for the basic fraction.
Technical Specifications:
| Property | Value |
|---|---|
| Sorbent | 8270 |
| Membrane type | Empore™ particle-loaded PTFE membrane |
| Disk diameter | 47 mm |
| Pack size | 20 disks/pack, 3 packs/case |
| Method compatibility | EPA Method 8270E, EPA Method 3535 |
| Target analytes | More than 125 SVOCs (neutral, acidic, and basic) |
| Typical sample volume | 250 mL aqueous samples |
| Typical recovery | >75% for most compounds (validated, n = 3) |
| Typical RSD | <15% for most compounds (validated, n = 3) |
| Recommended use | Combined stack with 2 × Empore™ Activated Carbon Disks |