Herolab UniCen M Universal Benchtop Laboratory Centrifuge

The air-cooled Herolab UniCen M is a benchtop laboratory centrifuge for workflows without active refrigeration. It reaches up to 18,000 rpm and 25,356 × g with TF 12.2 H Biosafe. Select the rotor by vessel and required RCF.

Request a configuration →

Price: On request

Herolab UniCen M Universal Benchtop Laboratory Centrifuge
SKU: LS-21 14 055 Categories: , Brand:

Technical specifications

Parameter Specification
Speed range 500–18,000 rpm in 100 rpm increments
Maximum RCF 25,356 × g with TF 12.2 H Biosafe
Swing-out capacity Up to 4 × 200 mL with TS 4.200
Refrigeration Air-cooled, without active refrigeration
Fixed-angle configuration 6 × 94 mL with the TF 6.94 Biosafe fixed-angle rotor (21 14 655)

Swing-out rotors

Rotor Vessel configuration Rotor maximum
TS 2.6 2–6 microplates, max. height 56 mm 3,000 rpm / 1,036 × g
TS 24.2 24 × 2.2 mL, six carriers 12,500 rpm / 12,927 × g
TS 4.200 4 × 200 mL with screw-cap buckets 4,300 rpm / 3,018 × g

Fixed-angle rotors

Rotor Vessel configuration Rotor maximum
TF 12.2 H Biosafe 12 × 1.5/2.2 mL 18,000 rpm / 25,356 × g
TF 12.8 H 12 PCR strips of 8 × 0.2 mL 12,000 rpm / 15,777 × g
TF 24.2 Biosafe 24 × 1.5/2.2 mL 15,000 rpm / 20,501 × g
TF 6.94 Biosafe 6 × 94 mL 8,500 rpm / 8,449 × g
TF 6.15/50 F 6 × 15 mL + 6 × 50 mL in one run 10,000 rpm / 10,460 × g

Use the appropriate carriers with the TS 2.6. The manufacturer lists the TS 24.2 with six four-tube carriers, a windshield and a sealing lid. Follow the lowest applicable limit of the rotor, vessel and adapter.

The UniCen M is air-cooled. For workflows requiring active temperature control, see the UniCen MR.

Choose the rotor for 94 mL or 100 mL vessels

The TF 6.94 Biosafe accepts six listed 94 mL tubes, for example thick-walled PC tubes Ø 38 × 102 mm (25 32 80), directly. On the UniCen M, the rotor is rated up to 8,500 rpm and 8,449 × g. Use the lower applicable limit for the rotor and vessels.

For 100 mL vessels, use the TS 4.200 swing-out rotor with one compatible adapter per bucket, up to four vessels per run. The catalogue pairs Herolab PC tube 25 33 00 with adapter 21 14 641. Adapter 21 14 643 is listed for the alternate 100 mL vessel format. Confirm vessel dimensions and allowed fill and RCF before ordering.

Controls and safety

APRI™ identifies compatible Herolab rotors. Overspeed protection, imbalance shutdown and motorised lid locking support safe operation. The catalogue touchscreen control panel supports direct RCF entry and stores up to 50 programs.

Herolab product details and rotor list → · Herolab technical data (PDF)

Herolab TF 6.15/50 F tube and adapter details →

Compare benchtop laboratory centrifuges →

Request a quotation for a specific configuration

Reference or configuration Selection information
LS-21 14 055 Touchscreen version, 230 V, single-phase, 50/60 Hz, per Herolab catalogue. Confirm the required version for the installation site.
Request TF 12.2 H Biosafe configuration → Fixed-angle rotor for small-volume tubes. Confirm the vessel RCF limit.
Request TS 4.200 configuration → Catalogue set with four 200 mL screw-cap buckets. Confirm the vessel and bucket combination.
Request TF 6.15/50 F configuration → Mixed 15 mL and 50 mL loads. Confirm the approved tubes and the current catalogue reference.
Request TF 6.94 Biosafe (94 mL tubes) → Fixed-angle rotor 21 14 655, for six listed 94 mL tubes.
Request a TS 4.200 configuration for 100 mL vessels → Up to four 100 mL vessels. Select the adapter to match the vessel.
Request TS 2.6 → 2–6 microplates, max. height 56 mm
Request TS 24.2 → 24 × 2.2 mL, six carriers
Request TF 12.8 H → 12 PCR strips of 8 × 0.2 mL
Request TF 24.2 Biosafe → 24 × 1.5/2.2 mL

Tell us your vessel format, working volume, sample count, target RCF and delivery destination. The quotation specifies the instrument, accessories, payment terms and estimated dispatch.

Can I reach the maximum RCF with 200 mL vessels?
The TS 4.200 swing-out rotor has a maximum of 3,018 × g on the UniCen M. The instrument maximum applies to the TF 12.2 H Biosafe.

Can I use my existing rotor or tubes?
Provide the instrument model and serial number, rotor marking, tube dimensions and tube RCF rating. We check the combination and any necessary buckets or adapters.

What is supplied with the laboratory centrifuge?
The quotation lists the selected instrument version, power supply, rotor, buckets and adapters. The rotor table identifies each configuration separately.

Which rotor can I use for 100 mL vessels?
Use the TS 4.200 swing-out rotor and the adapter for your exact vessel. Up to four 100 mL vessels fit per run.

Which rotor is suitable for microplates?
The TS 2.6 is listed for two to six microplates with suitable carriers. For configuration, provide the plate type, loaded height and number of plates.

Contact form
Enquiry / Quotation / Order
Phone:+49 (0)721 47080525
Fax:+49 (0)721 47080537
Email:info@lab-sun.de
Technical Customer Service
Phone:+49 (0) 721 47080579
Email:info@lab-sun.de