CDS Pyrolysis Systems and Modules for Py-GC-MS

Product-group reference: CDS-PYR-001

CDS systems and modules for Py-GC-MS analysis of polymers, microplastics and other materials. Select sample introduction and system capabilities to match your sample, method and existing GC/MS platform.

CDS Analytical Logo

Pyrolysis converts suitable organic samples into smaller compounds for separation and identification by GC/MS. The CDS range covers routine single-temperature analysis, programmed thermal studies and specialist high-pressure or UV-assisted experiments. The Cryo-mill is a separate sample preparation device, rather than a GC sample introduction module.

Systems and technical specifications

Model or module Technical overview
CDS 4000 Single-temperature Pyroprobe; up to 1300 °C; direct mounting on the GC injection port; 9 kg.
CDS 6150 DISC sample loading; programmable temperature sequences; up to 1300 °C; heated transfer line up to 350 °C; 16.3 kg.
CDS 6200 DISC and Tenax-TA focusing trap as standard; reactant-gas capability; optional mass flow controller; up to 1300 °C; optional TD tube, dynamic headspace, cryotrap and external reactor modules; 17.5 kg.
DISC module Vertical sample loading for compatible CDS 6150/6200 systems; programmable to 1300 °C; 1.5 kg.
Autosampler module 48 positions with dynamic loading; requires DISC on a compatible 6150/6200; gas pressure greater than 15 psi; 12 kg.
CDS HPR High-pressure Pyroprobe based on the 5200 platform; up to 1400 °C; maximum pressure 500 psi (3.4 MPa); catalyst reactor up to 800 °C; 25 kg.
Photoprobe UV irradiation module, 260–400 nm; adjustable light intensity; for 6150/6200 with autosampler; 1 kg.
Cryo-mill Cryogenic ball mill; up to 70 Hz; four 5 mL sample jars; liquid-nitrogen cooling; 25 kg.

Temperature-program capabilities depend on the instrument and software version. The required sequence, gas handling, sample geometry and GC/MS interface are checked for the proposed configuration.

Manufacturer information

CDS 4000 · CDS 6150 · CDS 6200 · HPR

These systems are supplied to an agreed configuration. The reference CDS-PYR-001 identifies this product group; it is not a manufacturer order number for a complete system.

System Ordering information
CDS 4000 Manufacturer references: 40P4-5020 (115 V) / 40P4-5021 (220 V). Confirm interface and supply scope.
CDS 6150 / CDS 6200 Specify GC/MS model, sample type, temperature programme, throughput and required options.
DISC / autosampler / Photoprobe Compatibility and mounting requirements must match the selected base system.
CDS HPR Manufacturer references: 5004-5103 (115 V) / 5004-5104 (220 V). Define pressure, reactor and gas requirements.
Cryo-mill Confirm vessels, accessories and supply voltage in the quotation.

For a quotation, send your sample details, analytical objective, GC/MS model, required capacity and installation country to info@lab-sun.de.

What is required for automation?

The optional 48-position autosampler requires a compatible 6150/6200 with DISC. Gas supply and mounting requirements are checked before ordering.

What needs checking for high-pressure or UV work?

HPR and Photoprobe are specialist configurations. Operating conditions, gas handling and required protective measures must suit the application and laboratory.