Labsun K1160 Fully Automatic Kjeldahl Analyzer for Nitrogen and Protein

K1160: automated distillation and titration after Kjeldahl digestion.

For nitrogen determination and method-dependent protein calculation in food, feed and other suitable samples. Define digestion, conversion factor, throughput and documentation together.

Price: On request

Labsun K1160 Fully Automatic Kjeldahl Analyzer for Nitrogen and Protein

Kjeldahl nitrogen and protein determination

The K1160 automates distillation and titration of previously digested samples, for example in food and feed quality control. Sample digestion is a separate preparation step. Protein is calculated from the measured nitrogen content using a factor appropriate to the sample and method.

Confirm before selection

  • Sample matrix, sample mass and applicable method
  • Digestion equipment and conditions, including fume treatment
  • Daily sample count, autosampler and documentation requirements

SH420F and S402 are complementary instruments for digestion and fume treatment. These instruments and the autosampler are included only when specified in the quotation.

The Labsun K1160 is a fully automatic Kjeldahl analyzer for nitrogen and protein determination. It automates distillation, titration, calculation, reporting, waste disposal, and self-diagnostics.

Technical Features

  • Fully automatic workflow from distillation through result documentation.
  • Supports connection to a 24-position autosampler for largely unattended batch analysis.
  • Documented burette dosing increments: 0.2, 0.4 or 1.0 µL per step; confirm the offered configuration.

Specifications and configuration

Item Item No. Description
1 LP-C020100011 K1160 fully automatic Kjeldahl analyzer
2 LP-C020200003 K9860 mid-level Kjeldahl analyzer

 

Question: Which tasks does the Labsun K1160 automate?

Answer: The K1160 automates distillation, titration, calculation, reporting, waste disposal, and self-diagnostics within the Kjeldahl workflow.

Question: Which determinations is the analyzer intended for?

Answer: The analyzer is intended for nitrogen and protein determination using the Kjeldahl method.

Question: Can an autosampler be connected?

Answer: Yes. According to the product description, a 24-position autosampler can be connected for largely unattended batch analysis.

Question: What burette dosing resolution is available?

Answer: Documented burette dosing increments: 0.2, 0.4 or 1.0 µL per step; confirm the offered configuration. The dosing increment is not the accuracy of the complete nitrogen determination.

Question: What should be clarified before ordering?

Answer: The ordering information lists Item No. LP-C020100011 for the K1160. Please confirm the sample matrix, required throughput, autosampler and accessories, applicable method, and documentation requirements.

Contact form
Enquiry / Quotation / Order
Phone:+49 (0)721 47080525
Fax:+49 (0)721 47080537
Email:info@lab-sun.de
Technical Customer Service
Phone:+49 (0) 721 47080579
Email:info@lab-sun.de